SOFTWARE / COMMERCIAL METERING
AlphaCENTER

Metering data, analytics and reporting
in a unified software environment.
Software for commercial metering data, from defining metering points to consumption analysis and reporting. Modules and functions are selected for each project.
Platform features
A unified environment for collecting readings, analysing consumption and reporting. The user interface combines facilities, devices and calculated data; dedicated modules handle specialised tasks.
A clear metering structure
Manage facilities, feeders and meters, and arrange metering points in hierarchical models. View information in tables, charts and on a map.
Analysis and diagnostics
Compare data over a selected period and identify maximum and average values. Check completeness, reconcile profiles with readings and review device events.
From data to reports
Flexible templates, batch reporting, and Excel and PDF exports. Check data availability before report generation and account for time zones.
Access and data protection
User permissions and roles, with activity logging. The Utilities module supports database backup and restoration.
Supports PostgreSQL, Postgres Pro and Oracle. Features depend on the installed edition and modules. User interface features ↗
Software editions: PE, SE and UE
The edition defines system scale and workstation count. Selection considers meter numbers, users and communications with facilities.
01 / LOCAL WORKSTATION
AlphaCENTER PE
AC_PE
A single-user system on one computer: automatic polling of meters and data acquisition units, calculations and data viewing.
- The licence is selected by meter count.
- Module AC_PE2 adds one network workstation.
02 / COLLABORATION
AlphaCENTER SE
AC_SE Standard / Pro
A server database and client workstations for a data acquisition and processing centre.
- Multiple staff work in a shared system.
- Standard and Pro editions have different limits.
03 / LARGE-SCALE SYSTEM
AlphaCENTER UE
AC_UE
An edition with no licensed limit on meters or workstations.
- An additional AC_COM server distributes the load or moves polling to a separate node.
- Servers and communication channels are sized for actual workloads.
Edition comparison
| Edition | Meters | Users / workstations |
|---|---|---|
| AC_PE | 10 / 20 / 30 / 40 / 50 / 100, depending on licence | 1; one additional workstation with AC_PE2 |
| AC_SE Standard | Up to 100 | Up to 5 |
| AC_SE Pro | Up to 500 | Up to 10 |
| AC_UE | No licensed limit | No licensed limit |
Limits are based on the developer’s catalogue dated 1 February 2026. For existing licences, parameters are checked against the protection key. Supply scope and terms for Kazakhstan are confirmed during selection. Adding modules requires active technical support.
Additional AlphaCENTER modules
Extensions and components for workstations, analytics, communications and system integration. Availability depends on the edition and licence. Expand an item to view features and conditions.
01AC_PE2 — additional workstationA second computer on the local network using the shared AC_PE database.
An AC_PE extension for installing client software on one more computer. It connects to the main computer over a TCP/IP LAN; the database remains on one computer.
Features
- Access the shared database from another computer without creating a separate metering database.
- Client software on a second workstation with a network connection to the main computer.
- Software-enforced limit: AC_PE supports no more than one additional workstation.
Suitable when a second computer needs access within the local network.
Compatibility and conditions: An AC_PE extension only. The final configuration is one main and one additional workstation.
02AlphaCENTER LaptopManual meter polling from a laptop and transfer to the database.
A laptop module for on-site reading collection. Manually polls meters through an optical port or RS-232 multiplexer and transfers collected data to the AlphaCENTER database.
Features
- Local manual polling of compatible meters through the specified interfaces.
- Export collected information for later import into the main metering database.
- Export data from AC_PE, AC_SE or AC_UE for later import into a remote AlphaCENTER database.
Suitable for field service and transfers between databases.
Compatibility and conditions: Supplied together with other AlphaCENTER editions. Support for specific meters and interface adapters is confirmed during selection.
03AlphaCENTER MonitoringElectrical diagrams, network parameters, balances and threshold alarms.
An operational viewing and monitoring tool for facility electrical diagrams. Uses meters and groups defined in the shared AlphaCENTER database.
Features
- A single-line electrical diagram editor for visualising the facility.
- Automatically displays commercial and technical data by feeder.
- View phase currents, voltages, power and angles from available device measurements.
- Calculate and display group metrics, including balances and total consumption.
- Raise alarms when monitored parameters exceed set thresholds.
Suitable for an energy engineer’s workstation, with the facility diagram and available current values in one interface.
Compatibility and conditions: An add-on for AC_PE, AC_SE and AC_UE. Displayed parameters depend on the devices and data received.
04AlphaCENTER Task ManagerManage operations manually, on a schedule and in a defined sequence.
Organises routine AlphaCENTER operations. Tasks can run manually, on a schedule or in a sequence, such as generating a file and then sending it.
Features
- Manage data export and import tasks.
- Start file transfers by email and other protocols through the relevant modules.
- Configure execution order and actions on completion or error.
- Review execution results in the task log.
Suitable for recurring operations, including KEGOC exchange with the Kazakhstan market and File Transfer modules.
Compatibility and conditions: Available task types depend on installed modules. Selection considers required operations and transfer channels.
05AlphaCENTER WebView data and reports in a browser with access controls.
Provides browser access to AlphaCENTER data over a corporate network or the Internet. For SE, UE and RTU-327, users can view information from multiple computers without installing the full client on each.
Features
- View metering data and available reports over HTTP or HTTPS.
- Configure access to facilities, meters and reports for different user groups.
- Work with profiles, readings, network parameters and events within assigned permissions and available data.
- REST API access to data in supported configurations.
Suitable for staff and customer browser access to selected facilities.
Compatibility and conditions: For AlphaCENTER SE, UE and RTU-327; Web does not work with PE. Requires a separate module licence, an IIS web server and a database connection. Account limits depend on the software edition.
06AlphaCENTER Kazakhstan Wholesale MarketExchange with KEGOC’s metering system for Kazakhstan wholesale market participants.
For Kazakhstan wholesale electricity market participants exchanging commercial metering data with the System Operator, KEGOC JSC. The module prepares measurement and event files from AlphaCENTER and imports received data into the database.
Add-on for AC_PE, AC_SE and AC_UE
Supplied to customers in Kazakhstan as part of an AlphaCENTER solution. Task Manager and File Transfer automate exchange; the package is selected for the installed edition and facility requirements.
01 / EXPORT Measurements and events for KEGOC
Generate files for selected metering points and codes, for a specified period or since the previous generation. Rounding with remainder carry-over is available.
02 / IMPORT Validate incoming data
Check file structure and code-to-metering-point mapping. Import valid records, save errors separately and configure replacement rules for previously imported values.
03 / AUTOMATION Scheduled exchange
Run file preparation and FTP delivery in sequence through Task Manager. A separate task handles arbitrary periods while preserving regular exchange settings.
04 / CONTROL Archive and error messages
Archive generated files and log execution results. The solution can be configured to resend accumulated files and notify the administrator by email on failure.
Software solution components
Module roles in KEGOC metering exchange Component Task AlphaCENTER Kazakhstan Wholesale Market Convert database records to KEGOC-format files and import received files into AlphaCENTER. Task Manager Manual launch, scheduling, operation sequencing and execution logs. File Transfer Deliver prepared files to the recipient’s FTP server and configure error handling. Data, formats and exchange settings
- Metering profiles: files
PCCI_….hstwith interval energy values; the published format description uses 15-minute intervals. - Events: files
EVE_….hstwith event information for measurement points. - Identification: map AlphaCENTER metering points to codes used in exchanges with the System Operator.
- Communication channels: FTP exchange over the Internet. The module description includes dedicated and switched channels; primary and backup connections follow the facility’s technical conditions.
- Receiving files: the participant’s FTP server and a directory accessible to the module for database import.
Preparing a Kazakhstan wholesale market participant for connection
- Technical conditions. Identify KEGOC requirements for channels, codes, data structure and transfer schedules at the facility.
- Metering points. Agree the data to send and receive and map codes to AlphaCENTER metering points.
- Configuration. Prepare directories, FTP connections and export/import tasks; configure schedules and error handling.
- Exchange testing. Perform test transfers and imports. Metering system connection follows KEGOC’s project approval and testing stages.
For solution selection, send Almaty Project your AlphaCENTER edition and version, metering point count, required exchange directions and available technical conditions.
Description based on developer documentation: purpose, export, import, exchange setup. Connection requirements: KEGOC metering system implementation stages. Implementation parameters follow facility technical conditions and the licence package.
- Metering profiles: files
07AlphaCENTER Report GeneratorCustom forms, Excel templates and scheduled reports.
Build reports from AlphaCENTER data blocks or populate existing company templates.
Features
- Configure report parameters, cells and formatting; import Excel templates.
- Excel export, preview, printing and PDF export.
- Batch reporting with relative dates, time-zone handling and data completeness checks.
Use and conditions: Automatic execution is configured with task execution tools. Report scope follows business requirements.
08AlphaCENTER Data Diagnostics and AnalysisData quality checks, facility maps and notifications.
Detect missing or inconsistent data and monitor metering status for selected facilities and groups.
Features
- Tables, charts and a map showing detected conditions.
- Reconcile profiles with readings, analyse meter replacements and review event logs.
- Check sets, results reports, and email and SMS notifications through configured channels.
Use and conditions: Diagnostic scenarios and notification recipients are configured for each facility.
09AlphaCENTER CommunicatorMeter and data acquisition unit communications, data collection and transfer.
The communications component manages exchanges with meters and data acquisition units. Device and service support is selected for the configuration.
Features
- Poll compatible devices over supported channels and protocols.
- Communication solutions use AMR, OPC and IEC 104 services; availability depends on the package supplied.
- Configure communications and interaction with the upper system level.
Use and conditions: Communicator and the additional AC_COM server are separate items. AC_COM extends the UE architecture for load distribution or remote polling.
10AlphaCENTER UtilitiesDatabase backup, restoration and maintenance.
Administrator tools for database protection and supporting operations.
Features
- Create and restore database backups; archive backup files.
- Automate backups using Windows Task Scheduler or Task Manager.
- Prepare diagnostic information and view software versions and database details.
Use and conditions: Available operations and backup methods depend on the DBMS and module version.
11AlphaCENTER File TransferSend and receive files by email, FTP and local network.
Transfers prepared files between systems and receives incoming files.
Features
- Send via SMTP, FTP and LAN; receive via POP3/IMAP and FTP.
- Send messages and files to Telegram when configured.
- Macro substitutions and result exchange between tasks, including file generation and delivery sequences.
Use and conditions: Works with the Kazakhstan market module and Task Manager for KEGOC exchange. Channels and transfer settings follow facility requirements.
12AlphaCENTER External Application LauncherIntegrate external applications and modules into automated tasks.
Adds application launches with command-line parameters to Task Manager workflows.
Features
- Launch Utilities for backups and Report Generator for reporting.
- Automate Communicator and diagnostics module operations.
- Pass information about generated files to other modules for further processing or delivery.
Use and conditions: Requires installed applications and configured launch parameters.
13AlphaCENTER Time Synchronisation · AC_TimeCorrect system clocks from a precise time source.
Synchronises computer or server time and can log clock corrections in AlphaCENTER.
Features
- Time sources: compatible GPS/GLONASS receivers with NMEA and SNTP servers.
- PPS support for compatible receivers and other sources listed in the documentation.
- Runs as a Task Manager task or through the standalone GPS Time Reader application.
Use and conditions: The time source, connection and required accuracy are selected during system design.
14AlphaCENTER MIR FormatsTransfer data to NPO MIR’s metering system.
Generates XML data for exchange with NPO MIR’s metering system.
Features
- Prepare files in a format supported by the receiving system.
- Use the module in inter-system data exchange tasks.
Use and conditions: Format and delivery settings are agreed for each integration.
AlphaCENTER documents
Documents are provided in their original languages. Changing the site language does not translate PDF files.
Features depend on the version, licence and modules. Description based on AlphaCENTER documentation: Plus, Report Generator, Utilities.
Sign in